Isolated and Combined footing design and check to NSCP 2015 / ACI 318-14, with a printable A4 technical report. RLN Centerline Engineering.
Preliminary design tool. A green check is not design approval. Results must be reviewed by the licensed engineer of record, who remains responsible for the design. Read Section 8 (Assumptions and Limitations) before relying on any result.
The suite contains two design modules in one window, with every command on the ribbon.
Each module checks service soil bearing, one-way shear, two-way (punching) shear and flexure, then gives preliminary bar counts. Each module keeps its own inputs, so you can switch between them without losing work.
Units: lengths in m (bar size in mm), forces in kN, moments in kN·m, strengths and stresses in MPa, soil pressure in kPa, densities in kN/m³.
| Tab / Group | Command | What it does |
|---|---|---|
| File | Open | Loads a saved project (.ftg or .json) into the active module. |
| Save / Save As | Saves the active module's inputs to a project file. | |
| Export / Print Report | Opens the print dialog for the active module. Choose "Save as PDF" to get a PDF. | |
| RLN Home | Returns to the RLN Centerline site. | |
| Home | Isolated / Combined Footing | Switches the active module. The inactive module keeps its inputs. |
| Manual / Auto-size | Chooses how the footing dimensions are set (see Sections 4 and 5). | |
| Design & Analysis, Technical Report, Detailed Calcs | Switches the workspace view. Return to Design & Analysis to edit inputs. | |
| Placement | Concentric / Edge / Corner | Isolated only: sets the column position on the pad. |
| Column 1 / Column 2 presets | Combined only: moves a column to a corner, edge or interior position. Disabled while Auto-size is on. | |
| Collapse arrow | The arrow at the right end of the tab row hides or shows the ribbon. | |
| Help | User Manual (F1) | Opens this manual. Press Esc to close it. |
Commands that do not apply to the active module are hidden or greyed out.
Plan size starts just larger than the column (column + 0.30 m) and grows in steps. For each plan size the tool first checks service bearing at the minimum thickness; sizes that fail are skipped. Thickness then increases in 50 mm steps up to the smaller of 2.0 m and Df, and the first combination that passes one-way shear, punching shear, flexure and bar spacing is selected. The plan size is limited to 10 m. If nothing passes, the tool tells you why (for example, Df too small, or edge / corner eccentricity too large). Switching back to Manual keeps the auto-sized dimensions so you can fine-tune them.
The results panel lists service bearing (qmax, qmin against qa, plus the moment sign check), one-way shear in both directions, punching shear, flexure in both directions (required steel, minimum steel and tension-controlled limit), bar spacing, and the governing check. The drawing shows plan and elevation with bars and dimensions.
Length: the footing is sized so the service-load resultant falls at the centroid, rounded up to 50 mm. If Column 2 would then fall outside the footing, its face is placed at the right edge (eccentric footing). The footing is extended beyond Column 1 as needed to keep the resultant within the middle third. Width: from net soil capacity (qa less footing and soil weight), with a minimum of the largest column Y-size + 0.30 m, increased until service bearing passes with the full eccentricity. Thickness: starts at 0.30 m and rises in 50 mm steps (to 2.0 m) until one-way shear, both punching checks and the flexural section check pass. The result panel states what governed each dimension. Turning Auto-size off keeps the sized values for manual editing.
The results panel shows service bearing (with the moment sign check), one-way shear at the governing section, punching shear at each column, longitudinal and transverse flexure, preliminary bar counts, and shear and moment diagrams from the longitudinal beam analysis. Auto-size is on by default so the starting inputs give a footing that passes every check.
.ftg or .json). Open reads it back. Files saved from one module cannot be opened in the other.Symbols: P axial load; M moment; A = Lx·Ly footing area; h thickness; d effective depth; f′c and fy material strengths; φ strength reduction factor; qa allowable bearing; Df founding depth; γc, γs concrete and soil unit weights.
Service: D + L
Factored: 1.4D
1.2D + 1.6L
Gravity cases only. Wind, seismic and other combinations are not included.
Wf = A · h · γc Ws = A · (Df − h) · γs (taken as zero if h > Df) W = Wf + Ws
Zx = Ly · Lx² / 6 Zy = Lx · Ly² / 6 q(max,min) = (P + W)/A ± |Mx|/Zy ± |My|/Zx Check: qmax ≤ qa and qmin ≥ 0 (no uplift)
Mx is paired with Zy and My with Zx. Confirm this matches how your loads are defined. Linear, full-contact pressure is assumed, and qa is treated as a gross value (it includes footing weight and overburden).
Isolated, edge and corner columns: eccentricity is modelled with 50 mm clearance from the footing edge to the column face.
ex = Lx/2 − cx/2 − 0.05 (edge and corner) ey = Ly/2 − cy/2 − 0.05 (corner) Mx(total) = Mx + P·ey My(total) = My + P·ex
Combined: the service resultant is found from the two column loads and positions. Moments about the footing centre are P1·(offset1 − L/2) + P2·(offset2 − L/2), plus the entered column moments.
Moment sign convention. Entered moments add algebraically to the eccentricity moments, so the sign matters when the column is eccentric.
Sign check. Whenever a column moment is entered, the results show the service pressure again with all entered moments reversed. It reads PASS if bearing still holds, or VERIFY if it would fail, in which case confirm the sign of your moments. Auto-size sizes the footing so that both signs pass.
Isolated: each case (1.4D and 1.2D + 1.6L) is evaluated as a coherent set. Axial load, moments, eccentricity and the factored footing and soil weight (factor 1.4 or 1.2) stay within the same case, and the case with the largest qu,max governs.
qu,max = Pu,total/A + |Mux|/Zy + |Muy|/Zx
Combined: the maximum axial envelope is combined with independent maximum absolute moment-component envelopes. These may not come from one load combination, which makes the pressure a conservative approximation. It is used for the transverse one-way shear check only; the beam analysis and the transverse bands use the net factored column loads (Section 7.9).
d = h − cover − db/2
One value of d is used for both directions.
φVc = φ · (1/6) · √f′c · b · d (ACI 318-14 simplified, §22.5.5.1)
Vu = qu,max · b · (overhang − d) in each direction, using the placement-adjusted overhang. Both directions are checked.Vu = qu · L · (overhang − d) against φVc with b = L, using the largest actual column-to-edge overhang in Y. The section with the higher demand / capacity ratio is reported as governing.The critical perimeter bo lies d/2 from the column faces. Where a footing edge is closer than d/2, the perimeter is truncated at the edge and that side carries no shear.
vc = min( 0.33√f′c ,
0.17(1 + 2/β)√f′c ,
0.083(αs·d/bo + 2)√f′c ) MPa
φVc = φ · vc · bo · d
β = long side / short side of the column
αs = 40 interior, 30 one side free, 20 two or more sides free
(ACI 318-14 Table 22.6.5.2)
Vu is the full factored column load. Soil reaction inside the critical perimeter is not deducted, which is conservative. Unbalanced moment transfer is not included. In the Combined module each column is checked separately with its own factored load.
Rn = Mu / (φ · b · d²) ρ = (0.85f′c/fy) · [ 1 − √(1 − 2Rn/(0.85f′c)) ] As,req = ρ · b · d β1 = 0.85 (f′c ≤ 28 MPa), else 0.85 − 0.05(f′c − 28)/7, not less than 0.65 ρmax = 0.85 · β1 · (f′c/fy) · (0.003/0.008) (tension-controlled, εt = 0.005) Section is inadequate if the square-root term is negative or ρ > ρmax.
Mu = qu,max · b · overhang² / 2 at the column face, in each direction. Minimum steel is As,min = ρmin · b · h, with ρmin = 0.0020 for fy < 420 MPa, otherwise max(0.0018·420/fy, 0.0014) (ACI 318-14 Table 24.4.3.2).Mu = Pu · b′² / (2B), where b′ is the larger overhang of that column in Y. The band width is the column width plus d/2 each side, limited by the footing edge or the mid-point of the gap between the columns. Steel is designed over the band width (n = max(3, ⌈max(As,req, As,min)/Ab⌉) per band), and minimum steel is placed over the remaining length.The footing is analysed as an inverted beam of length L. Column point loads Pu1 and Pu2 (each the larger of 1.4D and 1.2D + 1.6L for that column) act downward. A linear net soil reaction acts upward, in equilibrium with the factored column resultant:
xRes = (Pu1·x1 + Pu2·x2) / (Pu1 + Pu2) e = xRes − L/2 w(left) = (Pb/L) · (1 − 6e/L) w(right) = (Pb/L) · (1 + 6e/L) If either end value is negative it is set to zero (tensionless).
Shear and moment are evaluated at 400 stations along the footing. The sagging maximum governs the bottom steel, and the hogging maximum between the columns governs the top steel. The cantilever end moments are read from the same beam analysis at the column faces, so the shear, the longitudinal moments and the end moments all use one net-reaction basis. Column moments are not included in this beam analysis.
Ab = π/4 · db²
Isolated: n = max( 2 , ⌈max(As,req, As,min)/Ab⌉ , ⌈span/smax⌉ + 1 )
smax = min(3h, 450 mm)
clear spacing must be at least max(db, 25 mm)
Combined: n = max( 3 , ⌈max(As,req, As,min)/Ab⌉ ) for bottom and top layers
and for each transverse column band; minimum bars over the rest of the length
Rectangular isolated footings (ACI 318-14 §13.3.3.3): the long-direction bars are spread uniformly. Of the short-direction bars, the fraction γs = 2/(β + 1), with β = long side / short side, is placed in a central band equal in width to the short side. The clear spacing in that band is checked against the same minimum as above.
Depth above the bottom bars (ACI 318-14 §13.3.1.2), both modules: h − cover − 2db ≥ 150 mm. This is reported with the bar spacing check in the Isolated module and with the flexural check in the Combined module.
The Combined module does not check bar spacing, development length or anchorage.
| Item | Isolated | Combined |
|---|---|---|
| Factored bearing | Coherent per-case evaluation | Independent envelopes (conservative) |
| Minimum steel ratio | Same in both: 0.0020 for fy < 420 MPa, otherwise max(0.0018·420/fy, 0.0014) | |
| Minimum bar count | 2 | 3 |
| Bar spacing check | Yes (maximum, minimum, and central band for rectangular footings) | No |
| One-way shear | Both directions | Along the footing (beam analysis) and across it (transverse cantilever) |
| Flexural analysis | Cantilever at column face, gross factored pressure | Beam analysis (net factored column loads), with transverse design by column bands |
| Message or symptom | What to do |
|---|---|
| Workspace stays on "Loading" | The calculation libraries need an internet connection. Check the connection and reload. |
| Auto-size finds no solution (Isolated) | Increase Df, f′c, qa or the column size, or lower the minimum thickness. For edge or corner columns, consider a strap or combined footing. |
| Allowable soil pressure not enough (Combined) | The footing and soil weight use up qa. Increase qa or reduce Df. |
| Plan area impractically large | Increase qa, reduce loads or Df, or use another footing type. |
| Placement presets are greyed out | Turn Auto-size off (Home > Sizing > Manual). |
| Open reports "Invalid project file" | The file came from the other module or is damaged. Switch module and try again. |
Clause numbers are listed as they appear in the tool's own calculation sheets. Verify clause numbers against your copies of the codes, since NSCP 2015 section numbering differs from ACI 318-14.
Rev 3 (30 Oct 2026), second review pass: (1) The moment sign convention is now stated beside the load inputs, and a sign check with reversed moments is reported; auto-size sizes to the unfavourable sign. (2) Combined cantilever end moments now come from the beam analysis (net reaction) instead of the gross factored pressure. (3) Combined transverse steel is now designed by column bands instead of a uniform full-length strip, which raises the required steel under heavily loaded columns. (4) Combined defaults to Auto-size so the starting case passes. Combined designs with heavy columns may need more transverse bars than before.
Rev 2 (30 Oct 2026), calculation review: (1) Combined punching perimeter now truncated correctly at footing edges; previously bo was overstated for edge and corner columns (about 23% for a column flush with an edge). (2) Combined transverse one-way shear added. (3) Combined minimum steel now follows Table 24.4.3.2 (was a flat 0.0018). (4) Isolated central-band distribution for rectangular footings added. (5) 150 mm minimum depth above bottom bars added to both modules. Designs saved before Rev 2 or Rev 3 should be re-run.
© 2026 RLN Centerline Engineering. This manual describes the tool as built; if the calculation logic is changed, update this manual.