Concrete Stair Designer Project: Untitled Project v1.3.1 | Target basis: NSCP 2015 / ACI 318-14

Concrete Stair Designer: User Manual

Preliminary design tool. A green check is not design approval. Results must be reviewed by the licensed engineer of record.

1. Scope

One straight waist-slab flight with integral lower and upper landings, spanning in one direction between two supports, designed on a 1 m strip. Units: mm, kN, kPa, MPa, kN·m.

2. Quick start

  1. Enter project data, risers, tread, landing length, loads, materials and bars on the left.
  2. Choose Auto-size (Home > Sizing) to find the thinnest waist (5 mm steps) that passes flexure, shear and deflection, or Manual to keep your t.
  3. Read the checks, then use Technical Report and Detailed Calcs. File > Print gives an A4 sheet (Save as PDF).
  4. Save writes a .stg.json project file; Open reads it back.

3. Basis of calculations

  • Geometry: θ = atan(R/T); going = (N−1)·T; span L = going + landing (horizontal, centre to centre).
  • Loads per horizontal metre: flight = 24(t/cosθ + R/2) + finishes + railing/width; landing = 24t + finishes. Combinations 1.4D and 1.2D + 1.6L with full, flight-only and landing-only live load patterns.
  • Analysis: slope-deflection with a fixity factor f = k/(k + 4EI/L) at each end (0 pinned, 1 fixed), so a fixed end carries over to a pinned end (propped cantilever: hogging wL²/8). Constant EI. Positive and hogging moments and reactions follow; envelopes are plotted.
  • Flexure: φ = 0.90, Rn method, ρmin per fy, c/d ≤ 0.375, spacing ≤ min(3t, 450), practical spacing ≥ 75 mm. Top steel is designed for the hogging moment and extended past the inflection point by max(d, 12db).
  • Shear at d from the support face (half the support width plus d): φVc = 0.75·0.17√f′c·b·d, no stirrups.
  • Deflection: minimum thickness table (L/20, L/24, L/28 × (0.4 + fy/700), by number of restrained ends), or computed with Ie, ξ = 2.0 (limits L/360 live, L/240 long-term plus live).
  • Cover minimum by exposure (20 / 40–50 / 75 mm). Geometry limits: riser ≤ 200, tread ≥ 250, 2R + T = 600 to 650 mm; confirm against the National Building Code.
  • Auto-size finds the thinnest waist (5 mm steps from the minimum waist) that passes all checks. The Benchmarks view re-runs hand-checked cases.

4. Not included

Wind, seismic, vibration, stringer or side-supported stairs, transversely spanning landings, support beam design, laps and knee detailing. Reference development and hook lengths are shown, but anchorage is not checked. Live load defaults follow NSCP 2015 stairs and exitways; verify for your occupancy. Project data autosaves in this browser; use Save for a file.

5. Version history

  • 1.3.1: light interface by default (Home > Theme switches to dark), renamed Concrete Stair Designer with its own logo (RLN Centerline Engineering credited in the footer and report footers), auto-size fallback, legend fix.
  • 1.3.0: lower landing, concentrated tread load check, anchorage checks, design-basis sheet, report status watermark, engineer sign-off checklist, corrected stair section geometry.
  • 1.2.x: restraint by slope-deflection with fixity factors, computed deflection, bar options, quantities, DXF/SVG/PNG export, undo, revision history.

© 2026 Concrete Stair Designer by RLN Centerline Engineering.

Concrete Stair Designer by RLN Centerline Engineering © 2026. Preliminary stair analysis. Verify against your own judgement and the governing code.