Rainwater Filter Calculator – dual-media filtration, anthracite / silica sand on filter blocks or perforated pipe underdrain

Preliminary
ClearBedRainwater Filter Calculator – dual-media filtration, anthracite / silica sand on filter blocks or perforated pipe underdrain

Bed profile

Results

Catchment and first flush are handled in the system design; enter the peak flow to the filter (or the pump flow if a tank and pump feed it). Backwash with clean stored water. Blower: adiabatic power for a rotary lobe unit, air scour taken as free-air flow at site conditions; pipes sized by velocity (Hazen-Williams, Darcy for air, Manning for waste), nominal ID taken as DN. Units: water flows in m³/h (L/s and L/min shown only as conversions); air flow in m³/min of free air; filtration, wash and air-scour rates are flow per unit plan area (m/h = m³/m²·h); element dimensions (media, grain size, blocks, orifices) in mm; levels, depths and pipe lengths in m; pipe sizes DN in mm; heads and headlosses in m H₂O; pressures in kPa (gauge unless marked abs); velocities in m/s; masses in t, bulk densities in kg/m³. Perforated pipe underdrain: central manifold along the filter length with laterals on both sides, sized from orifice-area ratios (lateral ≥ 2 × its orifice area, manifold ≥ 1.5 × total lateral area) and the backwash pipe velocity limit; orifices are drilled downward and the pipes are buried in graded gravel (cover over laterals ≥ 150 mm). Orifice flow variation is an approximate velocity-head check. Air scour is taken through small orifices at the lateral crown or separate air laterals in the gravel: confirm with the supplier. Block grid: the nearest whole number of blocks is used, so the actual filtration rate can be up to 10% above the design rate (flagged beyond that). Terminal head: bed pressure at the media surface is taken as maximum water depth minus clogging headloss, assuming all clogging occurs at the surface (conservative); a negative value means air binding risk, so raise the water depth or lower the clogging allowance. Available head is the maximum water level down to the underdrain. Overlap water volume is included in wash water, and drain-down is taken from the maximum water level to 100 mm above the media. Wash trough width uses the free-discharge rectangular trough formula; weir loading assumes one lip of length L per trough and a sharp-crested nappe (q = 1.84·h^1.5), screened against a 75 mm nappe depth: confirm against your own criteria. The rate row shows how far the whole-block grid moves the filtration rate from the design rate, and warns when the filter is oversized by more than a third. The waste pipe carries flow only during short backwashes, so only a maximum velocity is checked. For a perforated pipe underdrain the layout must fit the filter (lateral at least 150 mm long, two or more laterals per side) or the results are marked invalid and printing and export are disabled. Preliminary design aid. Bed expansion is computed per layer (Richardson-Zaki, approximate): confirm with the media supplier. Air scour on dual media can intermix layers, so overlap water is held at the low rate. Clean-bed headloss uses Carman–Kozeny; check media specs, block manufacturer data and pilot results before final design.

Detailed drawing (A3 sheet)

Drawn to fit the screen. Pinch to zoom, or turn the phone sideways for a larger view.

Process schematic – filtration & backwash (pipes and valves)

Drawn to fit the screen. Pinch to zoom, or turn the phone sideways for a larger view.

Valve operation sequence

O = open, C = closed. V7 stays open whenever pump P-1 runs. Durations follow your air scour and water wash inputs.